Firmware checkpoints – IBM B50 User Manual
Page 78

Firmware Checkpoints
The following table contains a list of checkpoints issued by the firmware during
initialization.
Checkpoint
(hex)
Description
Repair Action
E100
Reserved/Unused
See “Unresolved problems” on page 3-26
E101
Video-enabled,
extended memory
test (Quick restart
path)
See “Unresolved problems” on page 3-26
E102
Firmware restart
with cfg'd parms
(Quick restart path)
See “Unresolved problems” on page 3-26
E103
Set memory refresh
(composite img)
See “Unresolved problems” on page 3-26
E104
Set memory refresh
(recovery block)
See “Unresolved problems” on page 3-26
E105
Transfer control to
O.S. (normal boot)
See “Boot Problems or Concerns” on page 3-27
E108
Run recovery block
base memory (test
2k), set stack
See “Unresolved problems” on page 3-26
E109
Copy CRC
verification code to
RAM
See “Unresolved problems” on page 3-26
E10A
Turn on cache
See “Unresolved problems” on page 3-26
E10B
Flush cache
See “Unresolved problems” on page 3-26
E10C
Jump to CRC
verification code in
RAM
See “Unresolved problems” on page 3-26
E10D
Compute composite
image CRC
See “Unresolved problems” on page 3-26
E10E
Jump back to ROM
See “Unresolved problems” on page 3-26
E10F
Transfer control to
Open Firmware
See “Unresolved problems” on page 3-26
E110
Turn off cache,
Check if composite
image CRC is valid
See “Unresolved problems” on page 3-26
3-14