Error Code

Function
/Description

Repair Action/Possible Failing FRU

25A80203

Unable to expand
target partition while
writing VPD data.

Refer to 25A80xxx.

25A80210

Setenv/$Setenv
parameter error -
name contains a null
character.

Refer to 25A80xxx.

25A80211

Setenv/$Setenv
parameter error -
value contains a null
character.

Refer to 25A80xxx.

25A80998

NVRAMRC script
evaluation error -
command line
execution error

Execution of a command line within the nvram
configuration variable “nvramrc” (script) resulted in a
“throw” being executed. This script can be modified by
the system firmware SMS utilities, the operating
system, PCI adapter rom code or utility, or an operator
(via the open firmware script editing command nvedit).
It may not be possible to resolve the problem without a
detailed analysis of the nvram script, the current
system configuration, and device tree contents.

1. The problem can be caused by a SCSI

adapter,whose SCSI bus ID has been changed
from the default setting, no longer appearing in the
system. This can be caused either by removing a
SCSI adapter, or a problem with a SCSI adapter.

a. Select the SCSI ID utility from the SMS

menu(s).

1) Verify the list of SCSI controllers/adapters.

If the list is not correct, suspect a problem
with the adapter(s) installed but not listed.

2) Select the option to save the configuration

information.

3) Restart the system.

b. If the problem persists, boot the operating

system and verify the SCSI bus IDs of any
installed/available SCSI controllers (change as
necessary), and restart the system.

2. Contact your service support representative for

further assistance.

25A80999

NVRAMRC script
evaluation error -
stack unbalanced on
completion.

This is a firmware debug environment error. There is
no user action or FRU replacement for this error.

3-8

7046 Model B50 Service Guide