IBM B50 User Manual
Page 85
Checkpoint
(hex)
Description
Repair Action
E1DC
Dynamic console
selection
If a console is attached but nothing is displayed on it,
follow the steps associated with “All display problems”
in the Entry MAP tables.
If selection screen(s) can be seen on the terminals and
the appropriate key on the input device associated with
the desired display or terminal is pressed, within
approximately 60 seconds, but there is no response to
the keystrokes:
1. If selecting the console with a keyboard attached
to the system, replace the keyboard. If replacing
the keyboard does not fix the problem, replace
system board (see note 3 on page 2-1).
2. If selecting the console with an ASCII terminal,
suspect the ASCII terminal. Use the Problem
Determination Procedures for the terminal.
Replace system board (see note 3 on page 2-1). if
these procedures do not reveal a problem.
Note: Terminal settings should be set to :
9600 Baud
No Parity
8 Data bits
1 Stop bit
E1DD
Early processor
exception
Replace system board (see note 3 on page 2-1).
See “Unresolved problems” on page 3-26
E1DE
Alternating pattern
of E1DE and E1AD
is used to indicate a
"Default Catch"
condition before the
Open Firmware
"checkpoint" word
(function) is
available.
Replace system board (see note 3 on page 2-1).
See “Unresolved problems” on page 3-26
E1DF
Create diskette drive
(disk) node
See “Unresolved problems” on page 3-26
E1E0
Program flash
See “Unresolved problems” on page 3-26
E1E1
Flash update
complete
See “Unresolved problems” on page 3-26
E1E2
Initialize System I/O
See “Unresolved problems” on page 3-26
E1E3
PReP boot image
initialization
See “Unresolved problems” on page 3-26
E1E4
Initialize Super I/O
with default values
See “Unresolved problems” on page 3-26
Chapter 3. Error Code to FRU Index