Step 1540-12

The server is working correctly with this configuration. One of the FRUs (adapters)
that you removed is probably defective,

1. Turn off the power.
2. Replace the riser card support bracket, as described in “Riser Card Support

Bracket” on page 7-10.

3. Install a FRU (adapter), and connect any internal cables and devices that were

attached to it.

4. Turn on the power.
5. Make sure the diagnostic CD-ROM disc is inserted into the CD-ROM drive.
6. If the Console Selection screen is displayed, choose the system console.
7. After the keyboard indicator is displayed, press the F5 key on the directly

attached keyboard or the number 5 key on an ASCII terminal keyboard.

8. Enter the appropriate password if you are prompted to do so.

Is the "Please define the System Console" screen displayed?

NO

Go to “Step 1540-13” on page 2-28.

YES

Repeat this step until all of the FRUs (adapters) are installed.

Go to

"

MAP 0410: Repair Checkout

"

in the Diagnostics Information for

Multiple Bus Systems.