Error Code

Function
/Description

Repair Action/Possible Failing FRU

21A00001

Test Unit Ready
Failed - hardware
error

Refer to 21A00xxx through 21A0004.

1. Replace the SCSI device.
2. Replace the SCSI cable.
3. Replace the SCSI controller.

|

4. Replace the power supply.

21A00002

Test Unit Ready
Failed - sense data
available.

Refer to 21A00xxx through 21A0004.

1. Replace the media (Removable media devices).
2. Replace the SCSI device.

21A00003

Send Diagnostic
Failed

Refer to 21A00xxx through 21A0004. Replace the
SCSI device.

21A00004

Send Diagnostic
Failed - DevOfl cmd

Refer to 21A00xxx through 21A0004. Replace the
SCSI device.

21E00xxx

SCSI Tape

Refer to error codes 21A00xxx through 21A0004 for a
description and repair action for the specific “xxx”
value.

21ED0xxx

SCSI Changer

Refer to error codes 21A00xxx through 21A0004 for a
description and repair action for the specific “xxx”
value.

21EE0xxx

Other SCSI device
type

Refer to error codes 21A00xxx through 21A0004 for a
description and repair action for the specific “xxx”
value.

21F00xxx

SCSI CD-ROM

Refer to error codes 21A00xxx through 21A0004 for a
description and repair action for the specific “xxx”
value.

21F20xxx

SCSI Read/Write
Optical

Refer to error codes 21A00xxx through 21A0004 for a
description and repair action for the specific “xxx”
value.

2200xxxx

Network Controller
problem

22000001

Internal wrap test
failed.

Replace the adapter.

22001001

Internal wrap test
failed.

Replace the adapter.

22002001

Adapter failed to
complete hardware
initialization.

Replace the adapter.

22010001

Adapter failed to
complete hardware
initilization.

Replace the adapter.

22011001

Adapter failed to
complete hardware
initilization.

Replace the adapter.