Checkpoint
(hex)

Description

Repair Action

E1EF

Erase flash

See “Unresolved problems” on page 3-26

E1F0

Start O.B.E.

See “Unresolved problems” on page 3-26

E1F1

Begin self-test
sequence on boot
device(s)

If the power light is flashing, see Firmware error
code "28A00040" repair action.
If the power light is on solid, see “Unresolved
problems” on page 3-26.

E1F2

Power-On Password
prompt

Prompt should be visible on the system console.

If a console is attached but nothing is displayed on it,
follow the steps associated with “All display problems”
in the Entry MAP tables.

E1F3

Privileged Access
Password prompt

Prompt should be visible on the system console.

If a console is attached but nothing is displayed on it,
follow the steps associated with “All display problems”
in the Entry MAP tables.

E1F5

Build boot device list

See “Unresolved problems” on page 3-26

E1F6

Determine boot
device sequence

See “Unresolved problems” on page 3-26

E1F7

No boot image
located

See “Unresolved problems” on page 3-26

E1FB

Scan SCSI bus for
attached devices

See “Unresolved problems” on page 3-26

E1FD

Default Catch

The operator panel will alternate between the code
“E1FD” and another “Exxx” code where “Exxx” is the
initialization point at which the error occurred. If the
“Exxx” code is not listed in this table, go to “MAP 1540:
Minimum Configuration” on page 2-17.

E201

Setup PHB BARC
addresses

Replace system board (see note 3 on page 2-1).

E202

Initialize PHB
registers and PHB's
PCI configuration
registers

Replace system board (see note 3 on page 2-1).

E203

Look for PCI to ISA
bridge

Replace system board (see note 3 on page 2-1).

E204

Setup ISA bridge
PCI config. registers
and initialize

Replace system board (see note 3 on page 2-1).

E206

Look for PRISM on
PCG and switch to
50MHz

Replace system board (see note 3 on page 2-1).

Chapter 3. Error Code to FRU Index

3-23