beautypg.com

IBM B50 User Manual

Page 66

background image

Error Code

Function
/Description

Repair Action/Possible Failing FRU

20A80002

Cannot get gateway
IP address.

Refer to “Firmware Checkpoints” on page 3-14, using
code E174.

20A80003

Cannot get server
hardware address

Refer to “Firmware Checkpoints” on page 3-14, using
code E174.

20A80004

Bootp failed

Refer to “Firmware Checkpoints” on page 3-14, using
code E174.

20A80005

File transmission
(TFTP) failed

Check network connection and try again.

20A80006

Boot image too
large. Ran out of
available firmware
memory resources
loading boot image.

Verify boot server configuration.

20D00xxx

Unknown or
Unrecognized
device

20D0000F

Self-test failed on
device, no
error/location code
information
available.

Check the SMS error log entry for this error code. The
location code (if present) in the error log entry should
identify the location of the failing device.

20D00010

Self-test failed on
device, cannot
locate package

Software Error (Contact your service representative for
assistance.)

20D00011

Cannot determine
Machine Model.

The Machine Model is part of the System Vital Product
Data. Perform corrective actions listed for errors
2BA00050, 2BA00051.

20E00xxx

Security

20E00000

Power-on password
entry error.

The password has been entered incorrectly.

Retry installing the password.

20E00001

Privileged-access
password entry
error.

The password has been entered incorrectly.

Retry installing the password.

20E00002

Privileged-access
password jumper
not enabled.

The privileged-access password jumper is not in the
correct position for password initial entry.

Consult the server User's Guide for pin location and
jumper position.

20E00003

Power-on password
must be set for
Unattended mode.

Unattended mode requires setting the Power-on
password before it is enabled.

20E00004

Battery drained or
needs replacement.

1. Replace battery

2. Replace system board (see note 3 on page 2-1).

3-2