IBM B50 User Manual
Page 70

Error Code
Function
/Description
Repair Action/Possible Failing FRU
25000xxx
Memory Controller
problem
25000000
Memory controller
failed
Replace system board (see note 3 on page 2-1).
25010xxx
Flash Update
problem
25010000
No diskette in drive.
Insert diskette containing firmware update file.
25010001
Diskette seek error.
1. Retry function.
2. Replace diskette drive.
3. Replace diskette cable.
4. Replace system board (see note 3 on page 2-1).
25010002
Diskette in drive
does not contain an
*.IMG file.
Insert diskette with firmware update file
25010003
Cannot open
OPENPROM
package.
Replace system board (see note 3 on page 2-1).
25010004
Cannot find
OPENPROM node.
Replace system board (see note 3 on page 2-1).
25010006
System ID does not
match image system
ID.
Make sure correct firmware update diskette is being
used with this system.
25010007
Image has bad
CRC.
Replace firmware update diskette.
25010008
Flash is write
protected, update
cancelled.
1. Turn off, then turn on the server and retry.
2. Replace system board (see note 3 on page 2-1).
25010009
Flash module is
unsupported or not
recognized.
Make sure correct firmware update diskette is being
used with this system.
2501000A
Flash write
protected.
1. Turn off, then turn on the server and retry.
2. Replace system board (see note 3 on page 2-1).
3-6
7046 Model B50 Service Guide