Cause, Solution, Device manager limitations – IBM 51 User Manual

Page 88: Some, Patch, Installations, Might, Fail, When, Trying

background image

v

When

you

look

at

the

properties

of

the

software

stack,

no

software

modules

are

displayed.

v

Compliance

checking

also

incorrectly

defines

the

software

stack

as

missing

when

the

software

stack

is

included

in

the

server

template.

Cause

You

can

associate

a

discovered

software

resource

with

a

software

product,

patch,

or

operating

system

software

definition

only.

Associations

with

a

software

stack

or

distributed

application

are

not

supported.

Solution

Avoid

associating

software

stacks

or

distributed

applications

with

identified

software

resources

on

a

server.

Some

patch

installations

might

fail

when

trying

to

perform

a

multiple

patch

installation

When

trying

to

perform

a

multiple

patch

installation,

some

patch

installations

might

fail.

The

following

error

message

is

displayed:

COPCOM116E

The

operation

timed

out.

Cause

Microsoft

limitations

to

multiple

patch

installation

can

cause

some

patch

installations

to

fail.

Solution

If

you

are

having

problems

installing

a

particular

patch,

you

might

need

to

perform

manual

steps

to

complete

the

installation.

Consult

Microsoft

article

296861

for

more

information:

http://support.microsoft.com/kb/296861

There

is

a

maximum

size

for

returnResult

parameter

storage

When

you

run

a

workflow

the

returnResult

parameter

stores

the

output

of

the

command.

If

the

results

are

too

large,

you

will

receive

an

error.

The

following

error

message

is

displayed:

COPDEX038E

A

database

error

occured:

The

value

of

a

host

variable

in

the

EXECUTE

or

OPEN

statement

is

too

large

for

its

corresponding

use

.

Cause

There

is

a

4000

character

limit

on

returnResult

parameter

storage

and

a

3800

character

limit

for

scriptlets.

Device

Manager

limitations

The

following

are

known

limitations

for

the

Device

Manager:

Running

lightweight

management

server

with

DB2

Universal

Database

generates

exceptions

Some

device

classes

(plug-ins)

are

not

configured

with

lightweight

device

management

server.

You

can

receive

exceptions

for

the

missing

device

classes.

However,

lightweight

device

management

server

will

start

and

run

with

its

more

limited

set

of

device

classes.

76

Tivoli

Intelligent

Orchestrator

Problem

Determination

and

Troubleshooting

Guide