GE DEH-210 User Manual
Page 100
94
•
Features of GE Large Faceplate Wizards
PMCS Interface Toolkit
Page
Value
Text Displayed
Description
2
CAUSE OF LAST TRIP
message
Message is a brief explanation of trip cause
3
PRE-TRIP AVERAGE MOTOR
CURRENT = xxx AMPS
4
PRE-TRIP U/B RATIO
(lI/Ip) xxx PERCENT
Unbalance
5
PRE-TRIP G/F CURRENT
G/F=xxx.0 AMPS
Units = *.1 if G/F CT
ratio = 2000:1
5
6
PRE-TRIP MAX STATOR RTD
RTD #XX = xxx C
7
PRE-TRIP AVERAGE VOLTAGE
VOLTS = xxx
Displayed only if MTM unit is installed in 269
8
PRE-TRIP KWATTS
KW = xxx
Displayed only if MTM unit is installed in 269
9
PRE-TRIP KVARS
KVAR = xxx
Displayed only if MTM unit is installed in 269
10
PRE-TRIP POWER FACTOR
PF = xxx
Displayed only if MTM unit is installed in 269
11
PRE-TRIP FREQUENCY
HZ = xxx
Displayed only if MTM unit is installed in 269
12
END OF PAGE FIVE
ACTUAL VALUES
Page footer
1
PAGE 6: ACTUAL VALUES
LEARNED PARAMETERS
Page header
2
LEARNED Istart (AVG OF 4
STARTS)=xxx AMPS
3
LEARNED Istart (last one)
=xxx AMPS
4
LEARNED K FACTOR
K = xxx AMPS
6
5
LEARNED RUNNING COOL
TIME-xxx MIN
6
LEARNED STOPPED COOL
TIME = xxx MIN
7
LEARNED ACCEL TIME
ACCEL TIME = xxx SEC
8
LEARNED Start Capacity
Required = xxx PERCENT
9
END OF PAGE SIX
ACTUAL VALUES
Page footer
1
PAGE 7: ACTUAL VALUES
METERING DATA
Page header
2
Vab = xxx Vbc = xxx
Vac = xxx (VOLTS)
or
MTM METER MODULE
NOT INSTALLED
Displayed only if MTM unit is on line
3
3 PHASE KWATTS
KW = xxx
Displayed only if MTM unit is on line