GarrettCom 6K32TRC User Manual
Page 9
Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)
4
www GarrettCom com
.
.
Fuse Required – 2Amps
24VDC Power Input Voltage : 20 to 40VDC
Fuse Required – 3Amps
125VDC Power and 100VDC Input Voltage : 88 to 300VDC
Fuse Required – 1Amps
Std. Terminal Block : “ -, GND, + ”
Power Consumption: same as for AC models, see above
Warning- All the fuse replacment must be replaced with same value.
For (Optional) DC internal power supplies at –48VDC, 24VDC and 125VDC,
including Dual Source options (
for continuity of operation when either of the DC
input sources are interrupted)
, see Appendices B and C.
Cooling
Method-
6K32T/ 6K32TR(Reverse)- Fan cooled (3 fans inside)
6K32TRC- Convection cooled (No fans) Static Thermal design techniques
Relay Alarm Contact (Optional)
The Alarm Contact option is offered as a configuration option.
The alarms can be
initiated through two normally closed Form-C contacts, one loss of power alarm
and one software alarm through user selectable software traps.
Per-port MDI or MDIX on RJ-45
The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45
ports., and eliminate the use of cross-over cable between the devices. Also
port-specific user settings (such as FDX or HDX, copper 10/100 speed) can
be fixed using software commands.
Agency
Approvals
UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15, Class A
NEBS L3 and ETSI Compliant, NEMA TS-2 for traffic control
IEEE 1613 Environmental Standard for Electric Power Substations.
See also Note for Power Substations in Section 3.2.4, 3.6.1, and 5.2.9
IEC61850 EMC and Operating Conditions Class C for Power Substations
Warranty:
Three years, return to factory
Made in USA
For a Configuration Guide, see the GarrettCom web site at
http://www.garrettcom.com/techsupport/insertion_guides/6k32trcg.pdf
(6K32)
http://www.garrettcom.com/techsupport/insertion_guides/6k32trccg.pdf
(6K32TRC)
for additional details.