Power Budget Calculations for Magnum 6K32T & 6K32TRC PM’s with
Fiber Media
Receiver Sensitivity and Transmitter Power are the parameters necessary to
compute the power budget. To calculate the power budget of different fiber media
installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = P
T
(min) - P
R
(min)
where P
T
= Transmitter Output Power, and P
R
= Receiver Sensitivity
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125
µm
(M.m) is 2.8 dB/km,
Module Model#
Gigabit
Gb Modules, fixed ports--SFP (Small Form Factor)
6KP2-2GSFP
2 SFP
6KP2-1GSFP1CU 1SFP
1 CU
6KP1-1SFP
1SFP
6KP1-1GCU
1 CU
Gb SFP fiber optic transceivers
SFP-SX
Gb SX, 850nm wavelength, 500 m distance
SFP-LX10
Gb LX, 1310nm wavelength, 10km dist
SFP-LX25
Gb LX, 1310nm wavelength, 25km
distance
SFP-ZX40
Gb ZX, 1550nm wavelength, 40km
distance
SFP-ZX70
Gb ZX, 1550nm wavelength, 70km
distance