GarrettCom 6K32TRC User Manual
Page 49
Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)
44
www GarrettCom com
.
.
connectors as shown in Fig. 3.5.3b . If the now empty slot is to remain unused, be sure
to install a 6KPM-BLNK face plate cover.
Figure 3.5.3b: Removing a 6KPM Card
Follow the step 8 to complete the process successfully.
NOTE:1. If the modular slot has not being used and moved to other unit, the empty
slot must be covered with Blank cover, to maintain proper air-inflow inside the unit
and keep off from dust and other unavoidable substance, otherwise can cause a failure
in the Switch.
2. If the PM module in the modular slot is not being installed properly or loose in
connection, the MNS-6K management software will not boot-up properly and a error
will generate as –{ failed to read register device type (offset 0x1600) on slot “A or B or
C or D”}, whichever the slot has been used.
3. Always boot-up the Switch after any new module installation on modular slot to
confirm the successful installation, before placing the chassis cover.
3.6
Connecting the Console Terminal to Magnum 6K32T & 6K32TRC
(Management)
Use a DB-9 “null modem” cable to connect the Magnum 6K32T & 6K32TRC
Console Port (the RS-232 port on the 6K32T & 6K32TRC Switch) to the your
PC, so that your PC becomes the 6K32T & 6K32TRC’s Console Terminal.
Note: The DB-9 cable does not include with the 6K32T & 6K32TRC
unit package.
Rear View of Magnum 6K32T
Note: For detail description of Managed Network Software (MNS-6K) and Magnum
6K32T & 6K32TRC Switch configuration for Network Management, please refer to
Magnum 6K32T & 6K32TRC Software Manual available on GarrettCom‘s FTP site.
Detail info. about the MNS is available on 2.2.9 ( see page no. 13) of this manual.
Console (DB-9)
Por
t
O
OF
CONSOLE
PORT