Checkref, Fadefault, Page | 33 – Gefen 1080P User Manual
Page 43
page | 33
#checkref
The
#checkref command displays information about the input signal on the Ref In
connector.
Syntax:
#checkref
Parameters:
None
Examples:
#checkref
Please wait...
Mesurment result: 262 lines , 6101 H sync period
Detect REF 18 , 480i , 262 lines , 6101 H sync period, 34720 XSET timing
Function completed
#fadefault
The
#fadefault command resets the routing and masking to factory-default settings..
This command is similar to the
command, except that the IP settings are
preserved.
Syntax:
#fadefault
Parameters:
None
Example:
#fadefault
Please wait...
Routed 1-1,2-2...
Function completed
Advanced Operation