Mechanical specifications

The computer conforms to the following mechanical specifications:

Environmental specifications

The following specifications identify maximum environmental conditions. At
no time should the computer run under conditions which violate these
specifications.

Server management

Monitoring, alerting, and logging of critical system information
obtained from embedded sensors on the system board, including
thermal levels, voltage levels, fan speeds, and chassis intrusion
monitoring.

Expansion slots

Two 64-bit, 66 MHz PCI slots on the riser card

Drive Bays

One CD drive bay (drive optional), one diskette drive bay, and three
hot-plug bays (at least one is occupied by a 1-inch high hot-plug
drive).

1U chassis case size

16.73 in. (424.9 mm) x 24.5 in. (622.3 mm) x 1.67 in. (42.42
mm) (WxDxH)

Weight

26.6 lbs (12.1 kg)

Temperature

Nonoperating

Operating

Maximum rate of change = 10° C per hour

-20.0° to 60.0° C (-4° to 140° F)

0° to 40° C (32° to 104° F); derated 0.5° C for every 1000 ft.
(305 m) *

Humidity

Nonoperating

Operating wet bulb

95% relative (noncondensing) at 30° C (86° F)

5%–85%Not to exceed 33° C (91.4° F) (with diskette drive
or hard disk drive)

Shock

Operating

Packaged

10.0 g, 11 msec, 1/2 sine

Operational after 30-inch free fall (cosmetic damage may
occur)

* Maximum temperature refers to the inlet air temperature, which is the ambient air
temperature within the rack cabinet, not the air temperature within the room.

8507328.book Page 108 Thursday, February 15, 2001 11:28 AM