beautypg.com

FUJITSU SPARC Enterprise Server M3000 User Manual

Page 99

background image

Chapter 6

Motherboard Unit Replacement

6-5

Caution –

To ensure that you and bystanders are not exposed to harm and to

prevent damage to the system, observe the ESD safety precautions. See

Section 1.1,

“ESD Precautions” on page 1-1

.

1. Power off the server.

This procedure includes the steps of turning the mode switch on the operator
panel to the Service position, verifying that the POWER LED is off, and
disconnecting the power cord. For details, see

Section 4.5.1, “Powering off the

Server” on page 4-12

.

2. Remove all the cables from the external interface block on the rear panel.

3. Pull the power supply unit out several centimeters to the rear side.

4. Slide the server out from the equipment rack.

For details, see

Section 5.1.1, “Sliding the Server Out from the Equipment Rack”

on page 5-1

.

Caution –

To prevent the equipment rack from tipping over, you must deploy the

antitilt feature, if applicable, before you slide the server out of the equipment rack.

Note –

When the cable management arm is not mounted, remove the cable ties that

secure the PCI cable to the rear of the server, and slide the server out.

5. Remove the top cover.

For details, see

Section 5.2.1, “Removing the Top Cover” on page 5-3

.

6. Remove the PCIe cards.

For details, see

Section 8.2, “Removing a PCIe Card” on page 8-4

.

7. Remove the air duct.

For details, see

Section 5.3.1, “Removing the Air Duct” on page 5-4

.

8. Disconnect all the cables from the motherboard unit.

9. Loosen the two screws securing the shutter unit, and slide the securing bracket

on the power supply unit.