3 mounting a fan unit, 4 reassembling the server, Mounting a fan unit – FUJITSU SPARC Enterprise Server M3000 User Manual
Page 151: Reassembling the server

Chapter 13
Fan Unit Replacement
13-5
13.3
Mounting a Fan Unit
Caution –
Do not forcibly mount a fan unit in a slot. Forcibly pushing a fan unit in
a slot may damage the fan unit or the server.
1. Adjust the position of the fan unit so that its latch is on the right when you are
facing the front of the server.
2. Insert the fan unit in the slot.
3. Complete the replacefru command which has been executed in the XSCF
command prompt. For details, see
Section 4.4.1, “FRU Removal and
Replacement (Power supply unit/Fan unit)” on page 4-8
.
13.4
Reassembling the Server
1. Attach the fan cover.
For details, see
Section 5.4.2, “Attaching the Fan Cover” on page 5-8
2. If the equipment rack is supplied with a Quake-Resistant Options Kit or
stabilizer, return to its original position.
For details, see
Section 5.1.2, “Sliding the Server into the Equipment Rack” on
3. From the XSCF Shell prompt, use the showhardconf command to verify that
the new fan unit has been installed.
For details, see
Section 4.4.2, “Verifying the Hardware Operation (Power supply
XSCF> showhardconf