Serial Port

C.2

UPC Port

TABLE C-1

Serial Port

Pin Assignment

Pin Number

Signal Name

Input/Output

Description

1

RTS

Output

Request to Send

2

DTR

Output

Data Terminal
Ready

3

TXD

Output

Send Data

4

GND

---

Ground

5

GND

---

Ground

6

RXD

Input

Receive Data

7

DSR

Input

Data Set Ready

8

CTS

Input

Clear to Send

TABLE C-2

UPC Port

Pin Assignment

Pin Number

Signal Name

Input/Output

Description

1

ER

---

---

2

NC

---

Not connected

3

NC

---

Not connected

4

NC

---

Not connected

5

SG

---

Ground

6

*BPS

Input

UPS hardware
error signal

7

*BTL

Input

Battery end of
discharge warning
signal

8

NC

---

Not connected

9

*ACOFF

Input

Power failure
detection signal

12 4 6 8

3 5 7

9 8 7 6

5 4 3 2 1