F-2

SPARC Enterprise M3000 Server Service Manual • March 2012

2. Select the device and confirm that the RAID volume is reported but inactive.

3. Use the activate-volume command to activate the RAID volume.

Note –

If there are multiple RAID volumes, they must be activated in descending

order, as shown below.

{0} ok select /pci@0,600000/pci@0/pci@0/scsi@0

{0} ok show-volumes

Volume 0 Target 82 Type IM (Integrated Mirroring)

Optimal Enabled Inactive

2 Members 585805824 Blocks, 299 GB

Disk 1

Primary Online

Target 0 FUJITSU MBD2300RC 3702

Disk 0

Secondary Online

Target 1 FUJITSU MBD2300RC 3702

{0} ok 0 activate-volume

Volume 0 is now activated

{0} ok show-volumes

Volume 0 Target 0 Type IM (Integrated Mirroring)

Degraded Enabled Resync In Progress

2 Members 585805824 Blocks, 299 GB

Disk 1

Primary Online

Target 8 FUJITSU MBD2300RC 3702

Disk 0

Secondary Online Out Of Sync

Target 1 FUJITSU MBD2300RC 3702

{0} ok 1 activate-volume

Volume 1 is now activated

{0} ok 0 activate-volume

Volume 0 is now activated