4.4.1

FRU Removal and Replacement (Power supply
unit/Fan unit)

Type the replacefru command from the XSCF Shell prompt.

The replacefru command is a menu-driven interactive command.

XSCF> replacefru

----------------------------------------------------------------------

Maintenance/Replacement Menu

Please select a type of FRU to be replaced.

1. FAN (Fan Unit)

2. PSU (Power Supply Unit)

----------------------------------------------------------------------

Select [1,2|c:cancel] :1

----------------------------------------------------------------------

Maintenance/Replacement Menu

Please select a FAN to be replaced.

No. FRU Status

--- --------------- ------------------

1. FAN_A#0 Normal

2. FAN_A#1 Normal

----------------------------------------------------------------------

Select [1,2|b:back] :1

You are about to replace FAN_A#0.

Do you want to continue?[r:replace|c:cancel] :r

Please confirm the Check LED is blinking.

If this is the case, please replace FAN_A#0.

After replacement has been completed, please select[f:finish] :f