beautypg.com

2 fmadm repair command, 3 fmadm config command, Fmadm repair – FUJITSU SPARC Enterprise Server M3000 User Manual

Page 56: Command, Fmadm config

background image

3-18

SPARC Enterprise M3000 Server Service Manual • March 2012

3.5.5.2

fmadm repair

Command

When the fmadm faulty command displays a fault, the fmadm repair command
must be executed to clear the FRU information in the domain after replacement of
the motherboard unit that has encountered the error. If the fmadm repair
command is not executed, the error message is not cleared.

If the fmadm faulty command displays a fault, clearing the FMA resource cache
on the operating system side causes no problem. Data in the cache does not need to
match the hardware fault information held by the XSCF.

3.5.5.3

fmadm config

Command

The fmadm config command output displays the version number and current
status of the diagnosis engine that is being used by the server. Whether the latest
engine is being used can be determined by consulting the My Oracle Support web
site.

# fmadm repair

STATERESOURCE / UUID

-------- --------------------------------------------------------

degraded dev:////pci@1e,600000

0ee65618-2218-4997-c0dc-b5c410ed8ec2

# fmadm config

MODULE VERSION STATUS DESCRIPTION

cpumem-diagnosis 1.6 active CPU/Memory Diagnosis

cpumem-retire 1.1 active CPU/Memory Retire Agent

disk-transport 1.0 active Disk Transport Agent

eft 1.16 active eft diagnosis engine

event-transport 2.0 active Event Transport Module

fabric-xlate 1.0 active Fabric Ereport Translater

fmd-self-diagnosis 1.0 active Fault Manager Self-Diagnosis

io-retire 1.0 active I/O Retire Agent

snmp-trapgen 1.0 active SNMP Trap Generation Agent

sysevent-transport 1.0 active SysEvent Transport Agent

syslog-msgs 1.0 active Syslog Messaging Agent

zfs-diagnosis 1.0 active ZFS Diagnosis Engine

zfs-retire 1.0 active ZFS Retire Agent