Calibrating the Card Lamination Module

s Lamination Sensor

Step

Procedure

1

Select the Lamination Tab's Sensors button to display options for calibrating
the Card Lamination Module

s Lamination Sensor. The Lamination Sensor is

what detects the start of each PolyGuard patch throughout the roll. This
Sensor may occasionally need to be recalibrated.

If the lamination module seems to skip PolyGuard patches or wind the

PolyGuard roll until the lamination module's LED flashes, recalibrate the
Lamination Sensor according to the instructions given the in the Calibration
window.

Be sure the Printer is powered ON and that the lamination module's Top

Cover and Lamination Station are closed when calibrating. (Note: This
Sensor is not used if applying Thermal Transfer Film overlaminate.)