beautypg.com

3 selecting the range – Furuno CH-250 User Manual

Page 53

background image

3-3

3.3

Selecting the Range

The [RANGE] control selects the detection (display) range, in 15 settings. Select the range
according to either the fish species being searched or the depth desired. Each time the control
is operated the newly selected range briefly appears in large characters at the screen top.
Range is permanently displayed at the top right-hand corner of the screen.

Normally the range is set so that the bottom is traced at the lower part of the screen (like an
echo sounder).

Surface

Bottom

RANGE m

Figure 3-3 Range concept

Default vertical fan mode range settings

Unit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Meters 10 20 30 40 60 80 100

120

160

200

250

300 400 500 600

Feet 30 60 90 120 150 200

250

300

400

500

600

800 1000 1500 2000

Note 1:

Unit of range measurement may be selected for meters, feet, fathoms, passi/braza or

Hiro (Japanese) with UNIT on the SYSTEM SETTING 1 menu. For details see page
5-10.

Note 2: