beautypg.com

Furuno CH-250 User Manual

Page 115

background image

SP - 3

E1316S01H

4.6

Vertical Fan Mode Control

Scanning Angle

6

°

to 180

°

, 12

°

step

Scanning Center

0

°

to 180

°

, 6

°

step

Scanning Step Angle

Normal: 3

°

, High speed: 6

°

Time to Train

360

°

, 6

°

step

4.7

Transceiver Beam Width

Frequency

Vertical

Horizontal

(-3 dB)

60 kHz:

12

°

15

°

88 kHz:

9.5

°

11.5

°

150 kHz:

6.5

°

6.5

°

4.8

Allowable Ship’s Speed

20 knot or less (15 knot during raise/lower operation)

4.9 Stabilizer

Within

30

°

, optional motion sensor or clinometers required

5 I/O

INTERFACE

5.1

Data format

IEC61162-1 (NMEA0183 Ver 1.5/2.0)

5.2

Input

DBS, DBT, DPT, GGA, GLL, HDG, HDM, HDT, MDA, MTW, RMA,

RMC, VDR, VHW, VTG

5.3 Output

SSTLL

6 POWER

SUPPLY

6.1

Display Unit/ Control Unit/ Transceiver Unit

12-32 VDC: 4.7-1.8 A, within 58 VA

6.2

Hull Unit

12/24-32 VDC: 4.7/2.3-1.8 A, within 58 VA

Max. 16.7/8.2-7.7 A, within 200-246 VA

6.3

Rectifier (option)

110/220 VAC, 13 A, 1 phase, 50/60 Hz

7 ENVIRONMENTAL

CONDITION

7.1

Ambient Temperature

-15°C to +55°C (Soundome: 0°C to +35°C)

7.2 Relative

Humidity

95%

7.3

Water proofing

Display/ Control unit: IPX5

(IEC 60529)

Transceiver unit/ Hull unit: IPX2

8 COATING

COLOR

8.1

Display Unit/ Control Unit Panel: N3.0, Chassis: 2.5GY5/1.5

8.2 Transceiver

Unit

N3.0