1 accessing a fan unit, 2 removing a fan unit, Accessing a fan unit – FUJITSU SPARC ENTERPRISE M3000 User Manual
Page 161: Removing a fan unit

Chapter 13
Fan Unit Replacement
13-3
13.1
Accessing a Fan Unit
Caution –
To ensure that you and bystanders are not exposed to harm and to
prevent damage to the system, observe the ESD safety precautions. See
1. From the XSCF Shell prompt, use the replacefru command to disable the fan
unit to be removed.
The replacefru command is a menu-driven interactive command. The
replacefru
continues operating while the fan unit is removed. Then later, it
performs the fan unit test. For details, see
Section 4.4.1, “FRU Removal and
Caution –
To prevent the equipment rack from tipping over, you must deploy the
antitilt feature, if applicable, before you slide the server out of the equipment rack.
Note –
When the cable management arm is not mounted, remove the cable ties that
fix the PCI cable to the rear of the server, and slide the server out.
2. Slide the server out from the equipment rack.
For details, see
Section 5.1.1, “Sliding the Server Out from the Equipment Rack”
.
3. Remove the fan cover.
For details, see
Section 5.4.1, “Removing the Fan Cover” on page 5-7
13.2
Removing a Fan Unit
1. While pressing the latch (1 in
), lift the fan unit (2 in
).
XSCF> replacefru