Chapter 8

Replacement and Installation of PCIe Cards

8-5

Note –

A card must be firmly secured so that it is properly mounted.

2. Install and tighten the one screw to secure the PCIe card in position.

8.4

Reassembling the Server

1. Attach the top cover.

For details, see

Section 5.2.2, “Attaching the Top Cover” on page 5-4

.

2. If the equipment rack is supplied with a Quake-Resistant Options Kit or

stabilizer, return to its original position.

For details, see

Section 5.1.2, “Sliding the Server into the Equipment Rack” on

page 5-3

.

3. Power on the server.

This procedure includes the steps of reconnecting the power cord, checking the
LED status, and turning the mode switch on the operator panel to the Locked
position. For details, see

Section 4.5.3.1, “Power-on by Using the XSCF

Command” on page 4-13

.

Note –

If automatic startup of the Solaris OS is specified, use the sendbreak -d

domain_id

command of the XSCF Shell to display the ok prompt after the display

console banner is displayed but before the system starts booting the Solaris OS.

4. Check the hardware.

This procedure includes the steps for running a program to verify that all the
components have been remounted and to start the Solaris OS.

For details, see

Section 4.5.4, “Verifying the Hardware Operation” on page 4-15

.