Chapter 6

Motherboard Unit Replacement

6-9

2. Install and tighten the four screws to secure the motherboard unit in position.

6.4

Reassembling the Server

1. Align the shutter unit with the securing bracket on the power supply unit, and

secure it with the two screws.

2. Mount the DIMMs.

For details, see

Section 7.4, “Installing the DIMMs” on page 7-9

.

3. Reconnect all the cables to their original connection destinations on the

motherboard unit.

4. Attach the air duct.

For details, see

Section 5.3.3, “Attaching the Air Duct” on page 5-6

.

5. Mount the PCIe cards

For details, see

Section 8.3, “Mounting a PCIe Card” on page 8-4

.

6. Attach the top cover.

For details, see

Section 5.2.2, “Attaching the Top Cover” on page 5-4

.

7. If the equipment rack is supplied with a Quake-Resistant Options Kit or

stabilizer, return to its original position.

For details, see

Section 5.1.2, “Sliding the Server into the Equipment Rack” on

page 5-3

.

8. Mount the power supply unit correctly.

9. Power on the server.

This procedure includes the steps of reconnecting the power cord, checking the
LED status, and turning the mode switch on the operator panel to the Locked
position. For details, see

Section 4.5.3.1, “Power-on by Using the XSCF

Command” on page 4-13

.

Note –

If automatic startup of the Solaris OS is specified, use the sendbreak -d

domain_id

command of the XSCF Shell to display the ok prompt after the display

console banner is displayed but before the system starts booting the Solaris OS.