beautypg.com

2 genlock synchronization, 3 timecode synchronization, Genlock synchronization – ARRI ALEXA Mini LF Ready to Shoot V-Mount Set (LPL) User Manual

Page 93: Timecode synchronization

background image

Synchronization

93

A

001_

A

H8B

A

001_C001_190705_

A

H8B

A

001_C002_190705_

A

H8B

A

001_C003_190705_

A

H8B

A

001_

B

H8B

A

001_C001_190705_

B

H8B

A

001_C002_190705_

B

H8B

A

001_C003_190705_

B

H8B

A

001_

C

H8B

A

001_C001_190705_

C

H8B

A

001_C002_190705_

C

H8B

A

001_C003_190705_

C

H8B

A

001_

D

H8B

A

001_C001_190705_

D

H8B

A

001_C002_190705_

D

H8B

A

001_C003_190705_

D

H8B

Note: Do not mix sensor and settings slaves as this will cause inconsistencies in clip naming.

19.2 Genlock Synchronization

The camera's sensor and SDI outputs can be synchronized to a reference sync signal (a tri-level HD

signal or an analog black burst signal) using the SYNC IN BNC connector. The camera's sensor needs

to run at equal or double the frame rate of the reference signal to establish synchronization.

Activation of Genlock

1. Connect the genlock source to the cameras SYNC IN connector.
2. Ensure that the camera's sensor frame rate matches (or is double) the genlock source frame rate.
3. Set

MENU > System > Sensor > Genlock Sync

to

SYNC IN

.

With Genlock Sync activated, the camera displays a genlock icon on the HOME screen

and in the status info of EVF/Monitor and the SDI outputs. The icon turns orange when

the camera can not synchronize to the genlock signal or if no signal could be detected.

In this case, see

MENU > Alerts

for detailed information.

Note: Simultaneous use of Timecode mode Jam-sync and Genlock is not supported.

Sync Shift

The Sync Shift option applies an offset to the genlock signal at the input. Minimum step size is 52 ns,

maximum possible correction is up to +/- 20 ms (= 384000 steps), depending on the sensor frame rate.
► Select

MENU > System > Sensor > Sync Shift

and apply the needed sync shift.

19.3 Timecode Synchronization

The camera's sensor and SDI outputs can be synchronized to a reference timecode signal using the 5-

pin TC connector. The camera's sensor needs to run at equal or double the frame rate of the reference

signal to establish synchronization.

Activation of Timecode Synchronization

1. Connect the timecode source to the cameras TC connector.
2. Ensure that the camera's sensor frame rate matches (or is double) the timecode source frame rate.
3. Set

MENU > System > Sensor > Genlock Sync

to

TC IN

.

With Genlock Sync activated, the camera displays a genlock icon on the HOME screen

and in the status info of EVF/Monitor and the SDI outputs. The icon turns orange when

the camera can not synchronize to the genlock signal or if no signal could be detected.

In this case, see

MENU > Alerts

for detailed information.

Note: Simultaneous use of Timecode mode Jam-sync and Genlock is not supported.