Main Parameters

58

Regen

Depending on the timecode run mode, regen behaves differently:
Run mode rec run: The camera determines the timecode of the last frame of

the last recorded clip and increments it by one for the next clip. This ensures

consecutive timecodes for a sequence of clips.
Run mode free run: The timecode source should be connected to the camera

permanently. The camera continuously reads the timecode signal at the time-

code connector as long as it is present. Upon disconnection or loss of signal,

the camera continues counting on its own, but will indicate the missing signal

through an orange exclamation mark on the TC button on the home screen.

When the external signal is reconnected, the camera uses the value of the ex-

ternal signal again. Regen mode will disable manual editing of the timecode.

Preset

The camera uses its internal counter.

Jam Sync

The camera samples the timecode value and simultaneously tunes its inter-

nal timecode clock to match the clock of the timecode source. During this pro-

cedure, the timecode display on the home screen, on the timecode menu

screen as well as on the status overlays is flashing. Jamming has finished

when the timecode display stops flashing, then the timecode source can be

disconnected. The camera continues counting based on its own high pre-

cision crystal clock now. This mode ensures stable timecode with a drift of

less than one frame over eight hours, after which the camera has to be re-

jammed.

Note:

Due to the tuning mechanism, jamming the camera might take up to 30

seconds and a timeout is issued if tuning could not be completed after 60 sec-

onds.

Regen Source

Based on the timecode run mode, the camera determines the timecode regen (regenerate) source

automatically. If the run mode is set to

Free run

, it regenerates timecode from the timecode input

connector. If set to

Rec run

, it regenerates timecode from the last clip of the recording media by

continuing seamlessly from the last active value.
► View

HOME > TC > Options > Regen Source

.

The regen source is displayed. The following settings are possible:

LTC In

timecode is continuously read from the TC connector.

Media

timecode from the last clip of the active recording card by continuing seam-

lessly from the last active value.

EXT

when camera is set to EXT sensor slave or EXT settings slave)

Timecode Offset

You can apply an offset to LTC input signals to compensate for timecode offsets in external devices.
1. Select

HOME > TC > Options > TC Offset

.

2. Adjust the timecode offset in the range of

-20

to

+20

frames.

NOTICE

The camera's internal battery will keep the timecode and timecode tuning values for about 10

minutes after the power source was disconnected.