Baseline Systems BaseStation 1000 User Manual
Page 57
BaseStation 1000 Irrigation Controller Manual
o
Less Than Limit – Select this option if you want the program to pause
when the moisture is less than the number in the Moisture Limit field.
In this case, the number in the Moisture Limit field represents the lower
limit.
o
Greater Than Limit – Select this option if you want the program to
pause when the moisture is greater than the number in the Moisture
Limit field. In this case, the number in the Moisture Limit field
represents the upper limit.
E. Switch Pause – If you have an event switch installed, you can use this condition to
have a program pause when a specified switch condition occurs.
a. Notice that the serial number for one of your event switches is highlighted in the
Event Switch field. If this is the serial number for the event switch installed in the
area that this program will water, no change is required. If you need to assign a
different event switch to the program, press the + or – button to select a different
serial number.
b. Press the button to highlight the Trigger field, and then press the + or – button
to alternate between “When Open” and “When Closed” to indicate which switch
condition will cause your program to pause.
c.
Press the button to highlight the Pause Hours field, and then press the + or –
button to indicate how many hours the program will pause when the switch
condition occurs.
Temperature Pause – If you have an air temperature sensor installed, you can use this
pause condition to have a program pause when a specified temperature is reached.
a. Notice that the serial number for one of your air temperature sensors is
highlighted in the Temp. Sensor field. If this is the serial number for the air
temperature sensor installed in the area that this program will water, no change is
required. If you need to assign a different air temperature sensor to the program,
press the + or – button to select a different serial number.
b. Press the button to highlight value in the Temperature Limit field, and then
press the + or – button to change the value in degrees Fahrenheit.
c.
Press the button to highlight one of the following pause options, and then press
the OK button:
o
Less Than Limit – Select this option if you want the program to pause
when the air temperature is less than the Limit.
o
Greater Than Limit – Select this option if you want the program to
pause when the air temperature is greater than the Limit.
Page 51