beautypg.com

Adjust for make up – Hawk Industries Hawkjaw Jr. Manual 65K-2GJR Serial Numbers 10 to 20 User Manual

Page 16

background image

Adjust for Make Up

2. Measure the tool joint with OD

calipers.

3. Use the 1 1/2" wrench to adjust

the Pointer (P) on the Pipe stop
index
(PI) to the OD tool joint
size.

4. For safety, adjust the Bottom

wrench nut (BN) 1" larger than
the Top wrench nut (TN) and
Middle wrench nut (MN).

5. Rotate the Top wrench nut (TN)

and the Middle wrench nut (MN)
to the OD tool joint size. Visually
align the end face (F) of the
wrench nut with the scale (S) on
the wrench.

6. Rotate Nut Lock (NL) down or

up to fix pipe size adjustment.

Shown set for 6 " OD tool joint

Shown set for 6" OD tool joint

S

F

BN

MN

TN

P

PI

16 Operation

NL