beautypg.com

Parameters comments, Example – HP E1459A User Manual

Page 49

background image

48

HP E1459A SCPI Command Reference

INPut

n:DEBounce:TIME? [MINimum | MAXimum | DEFault]

Returns the current debounce time for Port n as a floating point number formatted as
+d.ddddddE±ddd

Parameters

Comments

Ports 0 and 1 use the same debounce time, Ports 2 and 3 use the same debounce

time. For n = 0 or n = 1, this command returns the debounce time for both Ports
0 and 1; for n = 2 or n = 3, this command returns the debounce time for both
Ports both Ports 2 and 3.

Example

INP2:DEB:TIME?

Queries input circuit debounce time of
Port 2

Parameter Name

Parameter Type

Range of Values

Default

INPutn

DEFault

MINimum

MAXimum

numeric

numeric (floating pt)

0, 1, 2, 3

18.0

µ

sec through 9600 sec

Default 18.0

µ

sec

Minimum 18.0

µ

sec

Maximum 9600 sec

0

18.0

µ

sec

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com