background image

HP E1459A SCPI Command Reference

43

DISPlay:MONitor Subsystem

The DISPlay:MONitor subsystem turns on the monitor mode. Parameters related to
the state of the data and control lines are shown on an external terminal

1

. Refer to the

Command Module’s Users’s Guide for supported terminal types. The
DISPlay:MONitor commands do not apply to any C-SCPI or VXIplug&play driver
implementation. The parameters displayed are:

1.The display monitor is an RS-232 Terminal attached to an HP E1405B, E1406, or E1306 Command Module and

provides an interactive user interface to the HP E1459A.

Syntax

DISPlay:MONitor

:PORT <

port>

page 43

:PORT? [MINimum | MAXimum | DEFault]

page 44

:PORT:AUTO

page 44

:PORT:AUTO?

page 44

[:STATe] <

state>

page 45

[:STATe]?

page 45

DISPlay:MONitor:PORT <

port>

Sets the value of the DISPlay:MONitor:PORT or sets the automatic display mode.

Parameters

Comments

Sets the value of the Display Monitor to Port 0, 1, 2, or 3. AUTO automatically

displays the results of a MEAS:DIG:DATAn? command whenever that
command is executed for the monitored Port if the display monitor is active for
the Port. MINimum or DEFault sets the value for the monitored Port to 0.
MAXimum sets the value for the monitored Port to 3.

Specifying either 0, 1, 2, 3, MIN, MAX, or DEF turns the AUTO mode off.

*RST Condition: sets the display Port to 0 and the automatic display mode

ON.

Example

DISP:MON:PORT2

Display data from port 2

DISP:MON:PORT AUTO

Set automatic display mode

Parameter Name

Parameter Type

Range of Values

Default

<

port>

numeric or discrete

0, 1, 2, 3, AUTO, MINimum, MAXimum,

DEFault

AUTO