beautypg.com

Figure 4-2: communications loop routing, Tb3 inputs, Comm – Heat Controller Water Source Heat Pump User Manual

Page 85

background image

WattMaster WHP

Section 4

Start-Up and Troubleshooting

4-3

All communications wiring should be labeled to avoid confusion and to aid future
servicing.

COMPUTER
(OPTIONAL)

SYSTEM MANAGER

Remote Link

(OPTIONAL)

UNIT COMES WITH

STANDARD WALL MOUNT

120/24 VAC POWER SUPPLY

( MAY ALSO BE POWERED FROM 24VAC )

COMM LINK II

INTERFACE

(MULTIPLE LOOP)

TO OTHER MINILINKS

(NETWORK TERMINALS ONLY)

TO OTHER WHP CONTROLLERS

YS101716 REV. 1

SYSTEM MANAGER POWER SUPPLY

SHLD

COMMUNICATIONS

RS-485

R

T

GND

24VAC

POWER

LOOP

NETWORK

T

T

SH

SH

R

R

24V

A

C

GN

D

RELAY

OUTPUT

COM

1-3

OUT
OUT

1
2

COM

4-5

OUT
OUT
OUT

3
4

5

24VAC

24VAC

GND

GND

PWR

COMM

T

T

SHLD

SHLD

LD4

REC.

12V
AIN

1
2
3

4
5

GND
GND
AOUT

AIN

AIN
AIN
AIN

4-5

OUT

COMM

TEST

32K

8K

RAM

EPROM

ADDRESS ADD

PRESSURE

SENSOR

485

COMM

R

R

YS101564

EW

D

O

G

0-

5

VD

C

0-

1

VD

C

CPU

RELAY

OUTPUT

COM

1-3

OUT

OUT

1
2

COM

4-5

OUT

OUT
OUT

3
4

5

PWR

COMM

LD4

REC.

12V
AIN

1
2
3

4
5

GND
GND

AOUT

AIN

AIN
AIN
AIN

4-5

OUT

COMM

TEST

32K

8K

RAM

EPROM

ADDRESS ADD

PRESSURE

SENSOR

485

COMM

YS101564

EW

D

O

G

0-

5

VD

C

0-

1

VD

C

CPU

AIN1

AIN2

AIN3

AIN4

GND

AOUT1

YS101784

4 ANALOG IN MOD I/O BD.

4RLY IO BD.

4RLY IO BD.

YS101790

YS101790

2

4

V

A

C

G

N

D

RL

Y

1

D1

D2

D3

D4

D5

CX

3

RAM

EPROM

C3

C2

U6

P

H

IL

IP

S

CX6

C1

CX2

U2

U3

PAL

CX4

U4

TUC-5R PLUS

YS101816 REV. 2

V1

V2

V3

V5

V4

TB2

4

NETWORK

TOKEN

16

32

8

SW1

ADD

2

1

ADDRESS

V6

PO

W

ER

GND

24VAC

L1

D1

6

R6

C9

SC1

R1

1

U1

1

MC340

64A

D1

3

C16

9936

VR2

7824C T

M

TB4

R2

7

C13

R1

0

VR1

C1

9

C1

8

NE5090NPB3192

0PS

U8

CX

8

U9

X1

R7

D1

0

R13

D12

C7

CX10

U10

CX12

U12

U14

CX14

PJ

3

PJ

2

PJ1

EXPANSION

PRESSURE
SENSOR

T'STAT

C17

D15

R26

C20

R25

R24

R22

U15

CX13

U13

C15

R19

R15

C14

D1

8

D1

7

PU1

PU2

PU3

PU4

PU5

PU7

D6

D7

D8

D9

D11

D14

C12

C10

0-

5

VD

C

0-

1

VD

C

JP1

C1

1

X2

GND

TB3

INPUTS

GND

GND

+VDC

AIN1

AIN2

AIN3

AIN4

AIN5

AOUT1

AOUT2

AIN7

RN4

1

RN5

RS-485

CX5

U5

R

TB1

SHLD

T

COMM

COMM

RN3

1

RN1

U1

CX1

1

LD6

COMM

PWR

LD7

LED1

LED2

LD9

LD8

R1

U7

RV1
VREF ADJ

R28

+VREF

5.11V

TEST POINT

EWDOG

D19

RN2

1

COM1-3

COM4-5

R5

R4

R3

R2

R1

RL

Y

2

RL

Y

3

RL

Y

4

RL

Y

5

CX15

(1 MEG)

HH

P1

C2
1

03/31/04 03:38PM WED

OCCUPIED

NO ALARMS

Figure 4-2: Communications Loop Routing