Commlink ii interface, Figure 2-9: commlink interface wiring – Heat Controller Water Source Heat Pump User Manual

Page 37

background image

WattMaster WHP

Section 2

Installation and Wiring

2-13

CommLink II Interface

The CommLink II Interface provides for communications between the MiniLink
communication interfaces installed on the system. The CommLink II is required for
proper communications, even if a PC is not used. Locate the CommLink II near the
computer or modem if they are installed on the system. The cable connections between
the CommLink II and the computer or modem should be kept to less than twenty-five
feet. The CommLink II comes complete with computer and modem cables, and a plug-in
power supply.

Figure 2-9: CommLink Interface Wiring

COMPUTER
(OPTIONAL)

SYSTEM MANAGER

Remote Link
(OPTIONAL)

UNIT COMES WITH

STANDARD WALL MOUNT

120/24 VAC POWER SUPPLY

( MAY ALSO BE POWERED FROM 24VAC )

COMM LINK II

INTERFACE

(MULTIPLE LOOP)

TO OTHER MINILINKS

(NETWORK TERMINALS ONLY)

TO OTHER WHP CONTROLLERS

YS101716 REV. 1

SYSTEM MANAGER POWER SUPPLY

SHLD

COMMUNICATIONS

RS-485

R

T

GND

24VAC

POWER

LOOP

NETWORK

T

T

SH

SH

R

R

24V

AC

GN

D

RELAY

OUTPUT

COM

1-3

OUT
OUT

1
2

COM

4-5

OUT
OUT
OUT

3
4

5

24VAC

24VAC

GND

GND

PWR

COMM

T

T

SHLD

SHLD

LD4

REC.

12V
AIN

1
2
3

4
5

GND
GND
AOUT

AIN
AIN
AIN
AIN

4-5

OUT

COMM

TEST

32K

8K

RAM

EPROM

ADDRESS ADD

PRESSURE

SENSOR

485

COMM

R

R

YS101564

EW

D

O

G

0-

5

VD

C

0-

1

VD

C

CPU

RELAY

OUTPUT

COM

1-3

OUT

OUT

1
2

COM

4-5

OUT

OUT
OUT

3
4

5

PWR

COMM

LD4

REC.

12V
AIN

1
2
3

4
5

GND
GND
AOUT

AIN
AIN
AIN
AIN

4-5

OUT

COMM

TEST

32K

8K

RAM

EPROM

ADDRESS ADD

PRESSURE

SENSOR

485

COMM

YS101564

EW

D

O

G

0-

5

VD

C

0-

1

VD

C

CPU

AIN1

AIN2

AIN3

AIN4

GND

AOUT1

YS101784

4 ANALOG IN MOD I/O BD.

4RLY IO BD.

4RLY IO BD.

YS101790

YS101790

2

4

V

A

C

G

N

D

RL

Y

1

D1

D2

D3

D4

D5

CX

3

RAM

EPROM

C3

C2

U6

PH

IL

IP

S

CX6

C1

CX2

U2

U3

PAL

CX4

U4

TUC-5R PLUS

YS101816 REV. 2

V1

V2

V3

V5

V4

TB2

4

NETW ORK

TOKEN

16

32

8

SW1

ADD

2

1

ADDRESS

V6

PO

W

E

R

GND

24VAC

L1

D1

6

R6

C9

SC1

R1

1

U1

1

M C

34064A

D1

3

C16

9936

VR2

7824CT

M

TB4

R2

7

C13

R1

0

VR1

C1

9

C1

8

NE5090NPB3192

0PS

U8

CX

8

U9

X1

R7

D1

0

R13

D12

C7

CX10

U10

CX12

U12

U14

CX14

PJ

3

PJ

2

PJ1

EX PANSION

PRESSURE
SENSOR

T'STAT

C17

D15

R26

C20

R25

R24

R22

U15

CX13

U13

C15

R19

R15

C14

D1

8

D1

7

PU1

PU2

PU3

PU4

PU5

PU7

D6

D7

D8

D9

D11

D14

C12

C10

0-

5

VD

C

0-

1

VD

C

JP1

C1

1

X2

GND

TB3

INPUTS

GND

GND

+VDC

AIN1
AIN2

AIN3

AIN4

AIN5

AOUT1

AOUT2

AIN7

RN4

1

RN5

RS-485

CX5

U5

R

TB1

SHLD

T

COMM

COMM

RN3

1

RN1

U1

CX1

1

LD6

COMM

PWR

LD7

LED1

LED2

LD9

LD8

R1

U7

RV1
VREF ADJ

R28

+VREF

5.11V

TEST POINT

EWDOG

D19

RN2

1

COM1-3

COM4-5

R5

R4

R3

R2

R1

RL

Y

2

RL

Y

3

RL

Y

4

RL

Y

5

CX15

(1 MEG)

HH

P1

C2
1

03/31/04 03:38PM WED

OCCUPIED

NO ALARMS