beautypg.com

Sas and sata device numbers – HP DL365 User Manual

Page 73

background image

Component identification 73

HP Systems Insight

Display LED and color

Internal health

LED color

Status

PPM failure (amber)

Red

Integrated PPM has failed.

DIMM failure, slot X

(amber)

Red

One or more of the following conditions may exist:

DIMM in slot X has failed.

DIMM in slot X is an unsupported type, and no valid
memory exists in another bank.

Amber

One or more of the following conditions may exist:

DIMM in slot X has reached single-bit correctable

error threshold.

DIMM in slot X is in a pre-failure condition.

DIMM in slot X is an unsupported type, but valid
memory exists in another bank.

DIMM failure, all slots
(amber)

Red

No valid or usable memory is installed in the system.

Overtemperature (amber) Amber

The health driver has detected a cautionary temperature
level.

Red

The server has detected a critical temperature level.

Riser interlock (amber)

Red

The PCI riser board assembly is not seated properly.

Fan module (amber)

Amber

A redundant fan has failed.

Fan module (amber)

Red

The minimum fan requirements are not being met in one
or more of the fan modules. One or more fans have failed

or are missing.

SAS and SATA device numbers

Four hard drive configuration