beautypg.com

Adapter properties and configurations on netware – HP 441877-00F User Manual

Page 16

background image

Configuration and diagnostics 16

TCP Offload Engine (TOE). Enables the offloading of TCP connections to HP Multifunction Server

Adapters. Microsoft Scalable Networking Pack (SNP) is required.

o

Default = Enabled

o

Range = Disabled; Enabled

TOE will not work with the following features enabled: Windows Firewall; Internet Protocol security
(IPsec); Internet Protocol Network Address Translation (IPNAT); third-party firewalls; and NDIS 5.1

intermediate drivers. Download article number KB92222 from the Microsoft
(

http://www.microsoft.com

) website for more information.

Receive-Side Scaling (RSS). Enables dynamic load balancing of incoming traffic across CPUs.
Microsoft Scalable Networking Pack (SNP) is required.

o

Default = Enabled

o

Range = Disabled; Enabled

Adapter properties and configurations on Netware

A network device driver must be installed before the Gigabit Ethernet adapter can be used with your

Novell NetWare system. Before you can successfully install the adapter driver for Novell NetWare, the
adapter card must be physically installed in the server and, typically, NetWare OS software must already

be running on the server. Make sure that your server meets the hardware and operating system software

requirements.
For an adapter installation with an existing NetWare server, NetWare will automatically detect the new
adapter and attempt to load the appropriate driver.
To enable the Gigabit Ethernet adapter to function correctly, you need to install the latest support pack

files. The latest support pack can be found at the Novell website (

http://www.novell.com

).

Netware install program
A commonly used method to install a driver on a NetWare server is through NWCONFIG. The following

drivers are supported.
Driver configuration parameters

Parameter Options

Description

CheckSum =

Default = ON
Selections are: ON, OFF, Tx,
Rx

Enables or disables the transmit and receive
checksum off-loading feature. Checksum is

supported under NetWare 5.x only. If you

want to enable the CheckSum parameter, you
need to load it on the first instance.

Frame = type

Valid types are:
Ethernet_802.2,

Ethernet_802.3, Ethernet_II,

Ethernet_SNAP

Defines the frame type being used by this load
instance. Ethernet_802.2 and Ethernet_II are

the default values.

node =

NNNNNNNNNNNN

Specifies a node address in this field to
override the default Media Access Controller

(MAC) address (also known as the Locally
Administered Address)

name = text

Displays the name assigned to this adapter