ProSoft Technology MVI56E-DNPNET User Manual
Page 26

Contents
MVI56E-DNPNET ♦ ControlLogix Platform
User Manual
DNPNET Ethernet Client/Server Communication Module
Page 26 of 140
ProSoft Technology, Inc.
February 13, 2015
1
If you are not already online with the processor, open the Communications
menu, and
then choose D
OWNLOAD
.
RSLogix 5000 will establish communication with the processor.
You do not have to download through the processor's serial port, as shown here. You
may download through any available network connection.
2
When communication is established, RSLogix 5000 will open a confirmation dialog box.
Click the D
OWNLOAD
button to transfer the sample program to the processor.
3
RSLogix 5000 will compile the program and transfer it to the processor. This process
may take a few minutes.
4
When the download is complete, RSLogix 5000 will open another confirmation dialog
box. If the key switch is in the REM position, click OK
to switch the processor from
PROGRAM
mode to RUN
mode.
Note:
If you receive an error message during these steps, refer to your RSLogix documentation to interpret and
correct the error.
1.8.1 Configuring the RSLinx Driver for the PC COM Port
If RSLogix is unable to establish communication with the processor, follow these steps.
1
Open RSLinx.
2
Open the C
OMMUNICATIONS
menu, and choose C
ONFIGURE
D
RIVERS
.