ProSoft Technology MVI56E-MNETCR User Manual
Page 116

Reference
MVI56E-MNETCR ♦ ControlLogix Platform
User Manual
Modbus TCP/IP Multi Client Enhanced Communications Module for Remote Chassis
Page 116 of 159
ProSoft Technology, Inc.
June 14, 2011
5.4
Ethernet Cable Specifications
The recommended cable is Category 5 or better. A Category 5 cable has four
twisted pairs of wires, which are color-coded and cannot be swapped. The
module uses only two of the four pairs.
The Ethernet port on the module is Auto-Sensing. You can use either a standard
Ethernet straight-through cable or a crossover cable when connecting the
module to an Ethernet hub, a 10/100 Base-T Ethernet switch, or directly to a PC.
The module will detect the cable type and use the appropriate pins to send and
receive Ethernet signals.
Ethernet cabling is like U.S. telephone cables, except that it has eight
conductors. Some hubs have one input that can accept either a straight-through
or crossover cable, depending on a switch position. In this case, you must ensure
that the switch position and cable type agree.
Refer to Ethernet cable configuration (page 116) for a diagram of how to
configure Ethernet cable.
5.4.1 Ethernet Cable Configuration
Note: The standard connector view shown is color-coded for a straight-through cable.
Crossover cable
Straight- through cable
RJ-45 PIN
RJ-45 PIN
1 Rx+
3 Tx+
2 Rx-
6 Tx-
3 Tx+
1 Rx+
6 Tx-
2 Rx-
RJ-45 PIN
RJ-45 PIN
1 Rx+
1 Tx+
2 Rx-
2 Tx-
3 Tx+
3 Rx+
6 Tx-
6 Rx-