ProSoft Technology MVI69-FLN User Manual

Page 21

background image

Start Here

MVI69-FLN ♦ CompactLogix Platform

FA Control Network Communication Module

ProSoft Technology, Inc.

Page 21 of 137

November 3, 2008

4 When the download is complete, RSLogix will open another confirmation

dialog box. Click OK to switch the processor from Program mode to Run
mode.

Note: If you receive an error message during these steps, refer to your RSLogix documentation to
interpret and correct the error.

5 To verify that the processor is communicating with the module, open the Main

Program folder in the Controller Organization pane in RSLogix, and double-
click MainRoutine. You will be able to see the numbers change in Rung 0 of
the MainRoutine program.

Configuring RSLinx

If RSLogix is unable to establish communication with the processor, follow these steps:

1 Open RSLinx.
2 Open the Communications menu, and choose Configure Drivers.

This action opens the Configure Drivers dialog box.