occur, the NAS server can shut down itself automatically to prevent potential data loss.

To use smart-signaling UPS, connect UPS to the NAS server with an RS-232 or USB cable.

Then go to the “Server UPS Settings” menu on the administration page to enable UPS

support.

To use network-type UPS, connect the UPS to the LAN first. Then go to the “Server UPS

Settings” page on the administration page. Enable APC Smart UPS series、 USB UPS、

Generic serial UPS Type 1 and Type 2, select “Network UPS” from the “UPS Type” menu and

enter the UPS IP address and correct community.

Below are the shutdown options on the page.

Item

Description

Shut down

immediately when

battery is low

Specify whether to shut down the server when UPS battery is low.

Shut down in x

minutes when AC fails

Specify how many minutes to wait before shutting down the

server when a power event occurs.

Turn off UPS when

shut down by power

failure

If checked, the NAS server will turn off the UPS while it is shutting

down by power failure. If not, the UPS will still be working when

the server is shut down.