8.3 Checking Disk Status LEDs
The disk status LEDs report the condition of the disk drives:
Green – Normal disk drive function
Amber – Rebuilding to this disk drive
Red – Failed disk drive
Dark – No disk drive is installed
NAS-7400 Disk and System Status LEDs
8.4 Replacing a Failed Disk Drive
Replace the failed disk drive with a new disk drive of the same or slightly
greater capacity. You do not have to power down the NAS-7400.
i.
Open the NAS-7400’s front door.
ii.
Pull out the drive carrier with the failed drive.
iii.
Remove the failed disk drive from the drive carrier.
iv.
Install a new disk drive into the carrier.
v.
Place the carrier with the new disk drive back into the open slot in
the NAS-7400.
If the failed drive belonged to a RAID Volume, the RAID Volume will begin
rebuilding as soon as the new drive is installed.
During the Rebuild, the Disk Status LED shows amber. When the Rebuild is
finished, the Disk Status LED turns green.