beautypg.com

PLANET WGSW-50040 User Manual

Page 32

background image

3-15

Step 3: Login to the switch.

Login to the Web configuration interface. Valid login name and password are required, otherwise the switch

will reject HTTP access. This is a method to protect the switch from unauthorized access. As a result, when

Telnet is enabled for configuring and managing the switch, username and password for authorized Telnet

users must be configured with the following command:

username privilege [password (0|7) ]

To open the local authentication style with the following command: authentication line web login local.

Privilege option must exist and just is 15. Assume an authorized user in the switch has a username of

“admin”, and password of “admin”, the configuration procedure should like the following:

Switch>enable

Switch#config

Switch(config)#username admin privilege 15 password 0 admin

Switch(config)#authentication line web login local

The Web login interface of WGSW-50040 is as below:

Figure 3-10 Web Login Interface