PLANET GS-4210-24P2S User Manual
Page 84
![background image](https://www.manualsdir.com/files/865057/content/doc084.png)
User’s Manual of GS-4210-24P2S
The page includes the following fields:
Object
Description
Recovery Interval
The period (in seconds) for which a port will be kept disabled in the event of a port
error is detected (and the port action shuts down the port). Default is 300 seconds.
BPDU Guard
Enable or disable the port error disabled function to check status by BPDU guard.
Self Loop
Enable or disable the port error disabled function to check status by self loop.
Broadcast Flood
Enable or disable the port error disabled function to check status by broadcast
flood.
Unknown Multicast
Flood
Enable or disable the port error disabled function to check status by unknown
multicast flood.
Unicast Flood
Enable or disable the port error disabled function to check status by unicast flood.
ACL
Enable or disable the port error disabled function to check status by ACL.
Port Security
Violation
Enable or disable the port error disabled function to check status by port security
violation.
DHCP Rate Limit
Enable or disable the port error disabled function to check status by DHCP rate
limit
Enable or disable the port error disabled function to check status by ARP rate limit
ARP Rate Limt
Button
: Click to apply changes.
Figure 4-3-14:
Error Disabled Information Page Screenshot
84