: Click to apply changes.
By default, the system automatically detects the speed and duplex mode used on each port, and configures the path cost
according to the values shown below. Path cost “0” is used to indicate auto-configuration mode. When the short path cost
method is selected and the default path cost recommended by the IEEE 8021w standard exceeds 65,535, the default is set to
65,535.
IEEE 802.1D-1998
IEEE 802.1w-2001
Port Type
50-600
200,000-20,000,000
Ethernet
10-60
20,000-2,000,000
Fast Ethernet
Gigabit Ethernet
3-10
2,000-200,000
Table 4-6-1:
Recommended STP Path Cost Range
Port Type
Link Type
IEEE 802.1D-1998
IEEE 802.1w-2001
Ethernet
Half Duplex
Full Duplex
Trunk
100
95
90
2,000,000
1,999,999
1,000,000
Fast Ethernet
Half Duplex
Full Duplex
Trunk
19
18
15
200,000
100,000
50,000
Gigabit Ethernet
Full Duplex
Trunk
4
10,000
3
5,000
Table 4-6-2:
Recommended STP Path Costs
Port Type
Link Type
IEEE 802.1w-2001
Ethernet
Half Duplex
Full Duplex
Trunk
2,000,000
1,000,000
500,000
Fast Ethernet
Half Duplex
Full Duplex
Trunk
200,000
100,000
50,000
Gigabit Ethernet
Full Duplex
10,000
Trunk
5,000
Table 4-6-3:
Default STP Path Costs