Setup and programming, Scanner instruction manual, Overview – Precision Digital PD6080 User Manual
Page 25: Front panel buttons and status led indicators

PD6080/PD6081 Super Snooper Modbus
Scanner Instruction Manual
25
SETUP AND PROGRAMMING
The analog inputs of the scanner are factory calibrated prior to shipment to read in milliamps and volts,
depending on the input selection. The calibration equipment is certified to NIST standards.
Overview
There are no jumpers involved in the scanner setup procedure.
Setup and programming is done using ScanView software or through the front panel buttons.
After power and signal connections have been completed and verified, apply power to the scanner.
Front Panel Buttons and Status LED Indicators
PD6080 PD6081
Button
Symbol/LED
Description
LED
Status
Menu
1-8
Alarm 1-8 indicator
PREV/Right arrow/F1
1-8
M
Flashing: Relay in manual control
mode
NEXT/Up arrow/F2
/8
/16
Displays PV to nearest 1/8
th
or
1/16
th
of an inch
SCAN/Enter/F3
1-4
Flashing: Relay interlock switch
open
PREV
Go to previous PV
F
Communications Fault Condition
NEXT
Go to next PV
PAUSE
Press SCAN to pause scanning
STOP
Stop scan on alarm
PLAY
Press SCAN to resume scanning
Notes: F4 is a digital input. Alarms 5-8 are
enabled when relay expansion module installed.
Note: LEDs for relays in manual mode flash with
the “M” LED every 10 seconds.
• Press the Menu button to enter or exit the Programming Mode at any time.
• Press the Right arrow button to move to the next digit during digit or decimal point programming.
• Press the Up arrow button to scroll through the menus, decimal point, or to increment a digit.
• Press the Enter button to access a menu or to accept a setting.
• Press and hold the Menu button for three seconds to access the advanced features of the scanner.
• Press the SCAN/Enter button once to pause scanning (Pause LED flashes), then press the
SCAN/Enter button again to resume scanning (Play LED turns on).
• Press NEXT to go to the next PV; auto scan resumes after 10 seconds of inactivity.
• Press PREV to go to the previous PV; auto scan resumes after 10 seconds of inactivity.