Page 43

Appendix A – Specifi cations

Model

MSH3012M

MSH4024M

Inverter Specifi cations

Input battery voltage range

9.0 to 17.0 VDC

18.0 to 34.0 VDC

Absolute maximum DC input

25 VDC

35 VDC

AC output voltage accuracy

120 VAC ±3% (≤ continuous power)

Output frequency and accuracy

60 Hz ± 0.05 Hz

Total Harmonic Distortion (THD)

< 5%

Continuous power output (at 25°C)

3000 VA

4000 VA

Continuous AC output current

25 A

33 A

1 msec surge current (amps AC)

70

120

100 msec surge current (amps AC)

40

72

5 sec surge power (real watts)

3900

5800

30 sec surge power (real watts)

3800

5400

5 min surge power (real watts)

3200

4900

30 min surge power (real watts)

3000

4500

Maximum continuous input current

400 ADC

267 ADC

Inverter effi ciency (peak)

90.0%

93.7%

HBCO/HBCI (High Battery Cut Out/In)

16.8 VDC/16.5 VDC

33.6 VDC/33.0 VDC

LBCO/LBCI (Low Battery Cut Out/In)

9.0 VDC (adj)/12.5 VDC

18.0 VDC (adj)/25.0 VDC

Inverter stacking (series or parallel)

No

No

AC relay transfer time (minimum)

<16 msec

Power consumption – searching

<7 watts

Power consumption – inverting (no load)

30 watts

25 watts

Output waveform

Pure Sine Wave

Charger Specifi cations

Continuous charger output at 25°C

125 ADC

110 ADC

Input current for continuous rated output

18 AAC

28 AAC

Maximum current during load support

224 ADC

160 ADC

Charger effi ciency

87%

AC input frequency range

50 to 70 Hz

AC input voltage range

60 to 140 VAC (120 VAC nominal)

Power factor

> 0.95

General Features and Capabilities

Transfer relay capability

60 AAC maximum each input

Five-stage charging capability

Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™

Battery temperature compensation

Standard with available temp sensor connected (battery temp 0 - 50 °C)

Internal cooling

0 to 120 cfm variable speed drive using dual 92 mm brushless DC fan

Overcurrent protection

Yes, with two overlapping circuits

Over-temperature protection

Yes, on transformer, MOSFETS, and battery

Corrosion protection

PCB’s conformal coated, powder coated chassis/top, and stainless steel fasteners

Safety listings

ETL listed to UL/cUL 458, CSA C22.2 No. 107.1-01

Warranty

3 years parts and labor

Branch-rated output circuit breakers

No

Environmental Specifi cations

Operating temperature

-20°C to +60°C (-4°F to 140°F)

Non-operating temperature

-40°C to +70°C (-40°F to 158°F)

Operating humidity

0 to 95% RH non-condensing

Physical Specifi cations

Unit dimensions (length x width x height)

13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm)

Shipping dimensions (l x w x h)

19” x 17” x 13” (48.3 cm x 43.2 cm x 33 cm)

Mounting

Shelf or wall (vents not allowed to face downward unless ME-CB or MPX-CB is installed)

Weight

Unit: 55 lb (24.9 kg) / Shipping: 63 lb (28.6 kg)

Max operating altitude

15,000 ft (4570 m)

Specifi cations @ 25°C - Subject to change without notice.

Appendix A – Specifi cations and Optional Equipment

A-1 Inverter/Charger

Specifi cations