3.0 Operation

The MSH-M Series inverter has two normal operating routines: Inverter mode, which powers

your loads using the batteries, and Standby mode, which transfers the incoming AC current

(i.e., shorepower power or a generator) to power your loads and to recharge the batteries. This

inverter also includes an extensive protection circuitry to shut down the inverter under certain

fault conditions.

3.1 Inverter

Mode

When the MSH-M Series is fi rst powered up, it defaults to the OFF mode.

The momentary ON/OFF

power switch (

Item 1, Figure 1-1) m

ust be lightly pressed to turn the inverter ON. Subsequently

pressing this switch alternately turns the inverter OFF and ON.

Inverter OFF

When the inverter is OFF,

no power is used from the batteries to power the AC

loads, and

the status

LED will be OFF. If AC power from an external source (shorepower grid or

generator) is connected and qualifi ed on the inverter’s AC input, this AC input power will pass

through the inverter to power the AC loads. However, if this AC power is lost, the AC loads will no

longer be powered because the inverter is OFF.
When the inverter is turned ON, it operates either by “searching” or “inverting”, depending on the

connected AC loads.
Searching – When the inverter is fi rst turned ON, the automatic Search feature is enabled. This

feature is provided to conserve battery power when AC power is not required. In this mode, the

inverter pulses the AC output looking for an AC load (i.e., electrical appliance). Whenever an AC load

(greater than 5 watts) is turned on, the inverter recognizes the need for power and automatically

starts inverting. When there is no load (or less than 5 watts) detected, the inverter automatically

goes back into Search mode to minimize energy consumption from the battery bank. When the

inverter is searching, the inverter’s green LED fl ashes (fast).

Info: The factory default value for the Search feature is 5 watts. It can be turned off or

adjusted from 5 to 50 watts using a remote display.

Inverting

When a load greater than 5 watts is connected to the inverter output, the MSH-M

Series inverts the DC power from the battery and supplies 120 VAC power to your sub-panel. The

inverter’s green LED fl ashes once every 2 seconds (medium fl ash) to indicate it is inverting. The

amount of time the inverter can be inverting and

providing power is directly related to the amount

of AC loads that are connected, and the capacity of the battery bank. Refer to Figure 3-1 to see

the fl ow of power from the DC input to the AC output while in Inverter mode.

Neutral-Ground

Transfer Relay

AC Hot

Transfer Relay

NEUTRAL IN

AC GROUND

Power Transformer

FET Bridge

AC

DC

DC

IN

HOT OUT

DC POSITIVE

DC NEGATIVE

NEUTRAL OUT

INV

OUT

120

VAC

AC

Output

Relay

HOT IN

CB1

(60A)

CB2

(60A)

Figure 3-1, Power Flow – Inverter Mode