3.3 Current
Flow
The following fi gures show the current fl ow in the MSH-M Series during different modes:
Figure 3-4, MSH Current Flow – Inverting
Inverting – The MSH inverter converts the current from the battery to power the AC loads.
Figure 3-5, MSH Current Flow – Charging and AC Pass-thru
Charging and AC Pass-thru – The MSH inverter uses current from the grid/generator to power
the AC loads, and also converts this current to charge the battery.
Figure 3-6, MSH Current Flow – Charger Back-off
MSH Inverter
DC Current
(Battery)
0A
AC Loads
(Medium)
+20A
AC Current
(Grid/Gen)
-20A
Charger Back-off – When the AC loads increase, the MSH inverter reduces or stops the battery
charge current to allow the grid/generator to continue powering the AC loads.
MSH Inverter
DC Current
(Battery)
+10A
AC Loads
(Small)
+10A
AC Current
(Grid/Gen)
-20A
MSH Inverter
AC Current
(Grid/Gen)
0A
AC Loads
(Small)
+10A
DC Current
(Battery)
-10A