4.4 Performing an Inverter Reset

To perform an inverter reset (also known as a “soft reset”):
1. First, ensure all AC power (i.e., shorepower or generator) is removed from the inverter’s input.
2. Press and hold the Power ON/OFF pushbutton (see Figure 4-1) for approximately ten (10)

seconds until the Charging/Inverting Status LED comes on and fl ashes rapidly.

3. Once the rapid fl ashing has begun, release the Power ON/OFF pushbutton. The Status LED will

go off after the button is released.

4. After the inverter reset is completed, press the Power ON/OFF button to turn the inverter ON.
Some older inverter models do not allow an inverter reset. If the inverter reset fails, you will need

to perform a power reset using the procedure below. In either case, if an internal fault does not

clear, the inverter will require repair at a Magnum Authorized Service Center (ASC).

Info: The Power ON/OFF pushbutton is a small momentary type switch which operates

by lightly pressing and releasing. Be careful not to apply too much force when pushing

or the switch might break.

Figure 4-1, Performing an Inverter Reset

4.5 Performing a Power Reset

To perform a power reset (also known as a “hard reset”):
1. Remove all AC power (shorepower or generator) to the inverter.
2. Open all the inverter DC disconnects (or disconnect the positive battery cable to the inverter).
3. Ensure the inverter and the remote are disconnected from all AC and DC power (the remote

display will be blank).

4. After the inverter has been disconnected from all power for 30 seconds, reconnect the inverter

DC disconnects (or reconnect the positive battery cable) and resume operation.

Info: If DC disconnects are not used, there may be a momentary spark when the positive

battery cable is connected to the inverter’s terminal. This is normal and indicates that

the inverter’s internal capacitors are being charged.

2. Press and hold the Power

ON/OFF pushbutton.

3. Watch the Charging/Inverting

Status LED. After approximately

10 seconds it should come on

and fl ash rapidly to indicate the

inverter has reset. The Status LED

will go off after the pushbutton is

released.

1. Ensure all AC power

(i.e., shorepower or generator) is

removed from the inverter’s input.